Pipe Technology Performance
Double-wall corrugated pipes
NO.
Spec.
¡¡ZCVC-SB-1-1
OD110
¡¡ZCVC-SB-1-2
OD160
¡¡ZCVC-SB-1-3
ID225
¡¡ZCVC-SB-1-4
ID300
¡¡ZCVC-SB-1-5
ID400
The performance and technical criteria of the PVC-U double-wall corrugated pipes:
NO.
Items
Performance requirements
1
Voluntary standards
Production and inspection are carried out according to the enterprise standard of Q/ZCP010-2000,also referring to the standard of YD/T841-96 by the Ministry of Post & Telecommunications,and the trade standard of QB/T1916-93.
2
Appearance
Both the inside and outside surfaces of the pipe are not allowed to have blisters,crackles,overt impurities or irregular ripples.The inner surface should be smooth,without overt ripples or decompounded discoloration lines.Both ends of the pipe should be cut flat and vertical to the axial line.The color is yellow.
3
Loop piece rigidity
S1¡Ý4
S2¡Ý8
S3¡Ý16
4
Flat test
There should be no breaks,The two wall do not come away
5
Falling weight impact test
¡Ü10
6
Connection point penetrability
No leakage
7
Oven test
Neither lamination nor craze
8
Veika softening temperature
¡Ý79
9
Dichloromethane steeping
Inside and outside walls do not separate.There is no obvious burrs or fractures.